Title of article
Performance of reduced wall EPR insulated medium voltage power cables. II. Mechanical characteristics
Author/Authors
Yingli Wen Cinquemani، نويسنده , , P.L. ، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1997
Pages
6
From page
579
To page
584
Abstract
For the replacement of paper insulated lead
covered cables (PILC) reduced insulation wall designs have
been developed. They provide a reliable lower diameter cable
design for installation in existing PILC conduits. Representing
Part II of the investigation, this paper presents the results of
mechanical testing conducted on both reduced and full wall
EPR insulated cables. Both jacketed and non-jacketed cable
designs have been subjected to mechanical pulling forces
which greatly exceed recommended industry limitations,
followed by electrical testing to ascertain cable performance.
The results of this study conclude that reduced wall EPR
insulated cables can safely withstand the same pulling forces
as recommended for conventional walls and can be designed
for installation under the same pulling limitations.