Title of article
An application of dynamic safety system to pressurized water reactor
Author/Authors
Ung، نويسنده , , Soo Kim; Poong، نويسنده , , Hyun Seong ، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1998
Pages
13
From page
1221
To page
1233
Abstract
Abstract-The dynamic safety system (DSS) is a computer based reactor protection
system that has dynamic self-testing feature and fail-safe nature inherently.
The dynamic self-testing and fail-safe features provide a high level of
reliability and low spurious trip rate. The time and human efforts maintaining
the system can also be reduced by virtue of those features. In order to apply
the DSS for PWR, however, some modification is required because there exist
many differences between PWR and AGR for which the DSS was first tested
and installed. These differences are trip algorithms, monitored parameters, trip
logics, and other conditions. In this work, the DSS algorithm is modified for
PWR. The modified DSS has several new features which are required for
applying DSS technology to PWR. Then, the modified DSS is implemented in
a programmable logic controller (PLC) and tested. It is shown that, from the
results, the modified DSS generates correct output in all test cases
Journal title
Annals of Nuclear Energy
Serial Year
1998
Journal title
Annals of Nuclear Energy
Record number
405270
Link To Document