Title of article
Pressure equalised rainscreen joint modelling with the numerical model PERAM
Author/Authors
J. C. Burgess، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1995
Pages
5
From page
385
To page
389
Abstract
A process is developed to forecast cladding joint air pressure variations which affect rainscreen joint weathertightness in buildings, without recourse to experimental testing. A numerical model, PERAM, is presented to solve equations governing the pressure response of air within the cavity of a rainscreened joint in a building cladding when subjected to an external sinusoidal air pressure variation. A measure of the pressure equalisation performance of the joint as a percentage (the PEP) can then be calculated from the model waveforms derived, as a determination of the degree of weathertightness of the joint system. The PEPs calculated by PERAM are shown to fit the experimental data by incorporating two physically well-defined floating parameters into PERAM. This suggests that the model can be applied at the design stage of detailing weathertight pressure equalised cladding systems.
Journal title
Building and Environment
Serial Year
1995
Journal title
Building and Environment
Record number
408019
Link To Document