• Title of article

    Optimum overhang dimensions for energy saving

  • Author/Authors

    S. Raeissi، نويسنده , , S. M. Taheri، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1998
  • Pages
    10
  • From page
    293
  • To page
    302
  • Abstract
    A model is presented to predict the effect of window overhangs as passive cooling options on buildings. A computer program is written to calculate hourly cooling load requirements by the numerical solution of the energy balance equation for the building. This simulation is validated by comparison with field data taken from an actual house in Shiraz, Iran. A guideline is presented for optimum overhang dimensions concerning energy saving for buildings situated at latitudes of about 29.6 ° north. Results indicate that for the house under study (of popular size in Shiraz) summer cooling loads may be reduced by 12.7% by appropriate window shading, while only increasing winter heating loads by 0.6%.
  • Journal title
    Building and Environment
  • Serial Year
    1998
  • Journal title
    Building and Environment
  • Record number

    408183