Title of article
Contamination of indoor air by toxic soil vapours: the effects of subfloor ventilation and other protective measures
Author/Authors
B. A. Kiselman and V. V. Krylov، نويسنده , , C. C. Ferguson، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1998
Pages
17
From page
331
To page
347
Abstract
A steady-state analytical model is derived for estimating the concentration of vapour-phase contaminants in indoor air in houses with subfloor voids, given the contaminant concentration in bulk soil. The model includes the key mechanisms of transport and dispersion—contaminant partitioning into the soil-vapour phase, molecular diffusion, suction flow, stack effect, and ventilation, including contaminant transport by ventilation flow between subfloor void and living space. Using the model, different construction styles are examined from the point of view of their resistance to ingress of soil gases. Model results indicate that indoor air concentration depends strongly on wind velocity and on geometrical parameters of void and living space. Worked examples for houses of different construction styles illustrate the effects of wind velocity and house parameters on the concentration of benzene in soil that would give rise to its maximum permissible concentration in indoor air. Brief consideration is also given to concrete raft foundations and clean cover systems.
Journal title
Building and Environment
Serial Year
1998
Journal title
Building and Environment
Record number
408187
Link To Document