• Title of article

    Solar performance of hemispherical vault roofs

  • Author/Authors

    Victor M. Gomez-Munoz، نويسنده , , Miguel angel Porta-Gandara، نويسنده , , Christopher Heard، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    8
  • From page
    1431
  • To page
    1438
  • Abstract
    In hot climates, the improvement of comfort by passive solar techniques is a very important issue. In many parts of the world such as the Middle East, vault roofs are widely used in construction. The solar and energy performance of a hemispherical vault roof is studied, including the auto-shading instant effect during several days for different latitudes and throughout the year also. The results are compared with the standard horizontal flat roofing used in the typical modern low-cost housing in Mexico. The hemispherical vault receives around 35% less energy than the flat roof between the equinoxes, besides having other advantages such as a greater ceiling height, natural ventilation and illumination possibilities, and structural stability.
  • Keywords
    Hemispherical vault roof , shading , Solar control
  • Journal title
    Building and Environment
  • Serial Year
    2003
  • Journal title
    Building and Environment
  • Record number