• Title of article

    Impacts of some building passive design parameters on heating demand for a cold region

  • Author/Authors

    U. Teoman Aksoy، نويسنده , , Mustafa Inalli، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    13
  • From page
    1742
  • To page
    1754
  • Abstract
    In this study, the impact of passive design parameters such as building shape and orientation position on heating demand has been theoretically investigated. Therefore, a transient heat transfer problem in the building envelope with insulation and without insulation is solved by using the finite difference method. The considered buildings are placed on the ground with the azimuth angles from 0 to 90 . The heat loss per unit area of the buildings is computed by hour–hour and the yearly energy consumption of the buildings is also determined in the simulation model. The climatic data of Elazigˇ (38.4 N), a city located in a cold region of Turkey, are considered for the analysis. It is shown that buildings with a square shape have more advantages, and the most suitable orientation angles are 0 and 80 for buildings having shape factors (the ratio of building length to building depth ) 2/1 and 1/2, respectively.
  • Keywords
    Building passive parameters , Heating demand , Climatic comfort , Cold region
  • Journal title
    Building and Environment
  • Serial Year
    2006
  • Journal title
    Building and Environment
  • Record number

    409220