Title of article
Optimum insulation-thickness for thermal and freezing protection
Author/Authors
Y.F. Li، نويسنده , , B. Yao and W.K. Chow، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
11
From page
23
To page
33
Abstract
Methods for protecting water pipes, in cold regions against freezing, by thermal insulation
material and heating cable will be analyzed. Reliability of keeping the tube’s wall temperature
of a piping system at minimum value will be analyzed. A thermoeconomic optimization
analysis is applied with a simple algebraic formula derived for estimating the optimum insulation
thickness for tubes of different sizes. The optimization is based on a life-cycle cost
analysis. The effects of design parameters on the optimum thickness are investigated. Predicted
results of this study would provide useful reference data when considering design, practical
operation or maintenance.
Keywords
optimization , Freeze protection , Tube , Insulation thickness