• Title of article

    Performance of a showcase refrigeration system with multi-evaporator during on–off cycling and hot-gas bypass defrost

  • Author/Authors

    Honghyun Cho، نويسنده , , Yongchan Kim، نويسنده , , Inkyu Jang، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    16
  • From page
    1915
  • To page
    1930
  • Abstract
    During the defrosting process, the temperature in the cabinet of a showcase becomes higher than the set point. This phenomenon is undesirable for foods or products stored. It is essential to develop an efficient defrosting method to prevent large temperature fluctuations. In the present study, the performance of the showcase refrigeration system with three evaporators was measured during on–off cycling and hot-gas bypass defrost. Based on the test results, the effects of off-period in the on–off cycling and EEV opening in the hot-gas bypass defrosting cycle on the performance of showcase system were analyzed. In addition, the operating characteristics of the hot-gas bypass defrosting cycle were compared with those of the on–off cycling. The hot-gas bypass defrosting method showed higher refrigerating capacity and less temperature fluctuations than the on–off cycling under frosting/defrosting conditions even though it required more compressor power.
  • Journal title
    Energy
  • Serial Year
    2005
  • Journal title
    Energy
  • Record number

    416677