• Title of article

    Microclimate and ventilation in Estonian and Finnish dairy buildings

  • Author/Authors

    Frederick K. Teye، نويسنده , , Mikko Hautala، نويسنده , , Matti Pastell، نويسنده , , Jaan Praks، نويسنده , , Imbi Veerm?e، نويسنده , , V?ino Poikalainen، نويسنده , , Aime Pajum?gi، نويسنده , , Tapani Kivinen، نويسنده , , Jukka Ahokas، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    8
  • From page
    1194
  • To page
    1201
  • Abstract
    A series of ventilation, thermal and indoor air quality measurements were performed in 14 different dairy buildings in Estonia and Finland. The number of animals in the buildings varied from 30 to 600. Measurements were made all year round with ambient temperatures ranging between −40 °C and +30 °C. The results showed that microclimatic conditions in the dairy buildings were affected by the design of the building, outside temperature, wind, ventilation and manure handling method. The average inside air concentration of carbon dioxide was 950 ppm, ammonia 5 ppm, methane 48 ppm, relative humidity 70% and inside air velocity was 0.2 m/s. Although occasionally exceeded, the ventilation and average indoor air quality in the dairy buildings were mainly within the recommended limits.
  • Keywords
    Microclimate , Thermal comfort , Indoor air , ventilation , Cold , Warm , Uninsulated , Semi-insulated , Barns , Dairy buildings