• Title of article

    Flow pattern and model development for coaxially placed entry region coil-disc assembly as turbulence promoter in circular conduits

  • Author/Authors

    Vaka Murali Mohan، نويسنده , , P. Rajendra Prasad، نويسنده , , V. Sujatha، نويسنده , , S. Sarveswara Rao، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    6
  • From page
    1748
  • To page
    1753
  • Abstract
    Flow pattern and model development for coaxially placed entry region coil-disc as turbulence promoter in circular conduit have been presented in this paper. The electrolyte was equimolal potassium ferricyanide, potassium ferrocyanide and excess sodium hydroxide. The mass transfer correlation is based on law of the wall similarity. The variables covered in this study are the flow rate of the electrolyte, the geometric parameters of the promoter – pitch of the coil from 0.015 m to 0.035 m, length of the coil 0.01 m to 0.125 m, disc diameter from 0.02 m to 0.04 m, height of the disc from 0 m to 0.50 m, velocity of the fluid from 0.0591 m/s to 0.2751 m/s. The correlation may be extended to a wider range of parameters by virtue of the law of the wall. Experimental mass transfer function in terms of geometric parameters have been developed and presented.
  • Keywords
    Circular conduit , mass transfer , modeling , Entry region coil , Turbulence promoter , disc
  • Journal title
    Experimental Thermal and Fluid Science
  • Serial Year
    2007
  • Journal title
    Experimental Thermal and Fluid Science
  • Record number