• Title of article

    A predictive model of the reliabilities and the distributions of the acid concentrations, open-circuit voltages and capacities of valve-regulated lead/acid batteries during storage

  • Author/Authors

    K.R. Bullock، نويسنده , , M.C. Weeks، نويسنده , , C.S.C. Bose، نويسنده , , K.A. Murugesamoorthi، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1997
  • Pages
    7
  • From page
    139
  • To page
    145
  • Abstract
    A model is presented which can be used to determine the distribution of voltages, acid concentrations and capacities of stored, valveregulated (or sealed) lead/acid (VRLA) batteries with absorptive glass mats (AGM). Data taken on the self-discharge of six-cell, flat plate batteries are used to test the model. The actual capacities of cells stored at room temperature for up to two years correlate closely with capacities predicted by the model from measured open-circuit voltages. The model may also be used to predict capacities and voltages of cells stored at any temperature from data taken at only three temperatures.
  • Keywords
    capacity , Valve-regulated lead/acid batteries , Lead/acid batteries , Acid concentration , Open-circuit voltages
  • Journal title
    Journal of Power Sources
  • Serial Year
    1997
  • Journal title
    Journal of Power Sources
  • Record number