Title of article
Effect of radiation shield on pressure losses and power output of AMTEC cell
Author/Authors
M. A. K. Lodhi، نويسنده , , A. Daloglu، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
10
From page
258
To page
267
Abstract
Pressure loss in a PX-3A alkali metal thermo-electric converter (AMTEC) cell was investigated by varying the heat radiation between the beta alumina solid electrolyte (BASE) and the condenser. Chevron radiation shields were used to change the heat radiation between the BASE and the condenser in different numbers and at different angles. Results show that the pressure losses and also the pressure on the cathode side increase using chevron shields. The cell electrical power output and the cell efficiency decrease as the pressure on the cathode side increases when chevron shields are placed. The power output and efficiency increase as the chevron angle increases up to a certain limit.
Keywords
AMTEC , Pressure losses , Chevron radiation shields , Power output , Efficiency
Journal title
Journal of Power Sources
Serial Year
2001
Journal title
Journal of Power Sources
Record number
440392