• Title of article

    Effects of reverse voltage and subzero startup on the membrane electrode assembly of a PEMFC

  • Author/Authors

    Hongwei Wang، نويسنده , , Junbo Hou، نويسنده , , Hongmei Yu، نويسنده , , Shucheng Sun، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    6
  • From page
    287
  • To page
    292
  • Abstract
    Effects of reverse voltage and frozen fuel cell startup on the membrane electrode assembly (MEA) were investigated for a proton exchange membrane fuel cell (PEMFC). A single cell was started from a subzero temperature by applying reverse voltage. The voltages applied to the cell were 0.8 and 1.2 V. The fuel cell performance was measured with a polarization curve and by cyclic voltammetry (CV), electrochemical impedance spectra (EIS), linear scan voltammetry (LSV) after each experiment. From the results, it was concluded that the catalyst activity, electrochemical active surface area (ECA) and the membrane were not damaged by the reverse voltage if the voltage was below 0.85 V. In contrast, a reverse voltage improved cell performance slightly. If the reverse voltage was larger than 0.85 V, the cell performance degraded. Another single cell with an active area of 128 cm2 was started up at −15 °C by applying reverse voltage. The cell performance and MEA physical characteristic were tested before and after the freeze startup. From the results, the cell performance decayed MEA delamination was observed and the pore size distribution of the MEA changed.
  • Keywords
    Degradation , Hydrogen pump , Reverse voltage , PEMFC , MEA
  • Journal title
    Journal of Power Sources
  • Serial Year
    2007
  • Journal title
    Journal of Power Sources
  • Record number