• Title of article

    Cycling of three solid oxide fuel cell types

  • Author/Authors

    Waldemar Bujalski، نويسنده , , Chinnan M. Dikwal، نويسنده , , Kevin Kendall، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    5
  • From page
    96
  • To page
    100
  • Abstract
    One of the key problems of SOFCs is their slow start-up and cycling performance which is due to the thermal shock problems of zirconia electrolyte and its associated electrode and interconnect materials. Typical start-up times range from 2 to 6 h. Faster cycles can cause degradation in performance and in material integrity. The purpose of this paper is to study the transient performance of SOFCs under various (e.g. thermal and/or current load) cycling conditions, typifying start-up and shut-down as well as variable working conditions of the systems, in order to understand the degradation mechanisms. Three types of SOFC have been compared; the planar stack with metal interconnects represented by the Forschungszentrum Jülich (FZJ) configuration; the Rolls Royce Fuel Cell Systems Ltd. (RRFCS) integrated planar tube; and the Adelan pure tube. The objective was to cycle in temperature from ambient to the operating condition several times to check if degradation was occurring. To obtain thermally shock resistant systems, cell dimensions had to be reduced to the millimeter scale.
  • Keywords
    RRFCS , Tubular , Adelan , Cycling SOFC , Thermal cycles , planar , Integrated planar , FZJ
  • Journal title
    Journal of Power Sources
  • Serial Year
    2007
  • Journal title
    Journal of Power Sources
  • Record number

    441666