• Title of article

    Sensorless freehand 3D ultrasound in real tissue: Speckle decorrelation without fully developed speckle

  • Author/Authors

    Andrew H. Gee، نويسنده , , R. James Housden، نويسنده , , Peter Hassenpflug، نويسنده , , Graham M. Treece، نويسنده , , Richard W. Prager، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    13
  • From page
    137
  • To page
    149
  • Abstract
    It has previously been demonstrated that freehand 3D ultrasound can be acquired without a position sensor by measuring the elevational speckle decorrelation from frame to frame. However, this requires that the B-scans contain significant amounts of fully developed speckle. In this paper, we show that this condition is rarely satisfied in scans of real tissue, which instead exhibit fairly ubiquitous coherent scattering. By examining the axial and lateral correlation functions, we propose an heuristic technique to quantify the amount of coherency at each point in the B-scans. This leads to an adapted elevational decorrelation scheme which allows for the coherent scattering. Using the adapted scheme, we demonstrate markedly improved reconstructions of animal tissue in vitro.
  • Keywords
    Freehand 3D ultrasound , Coherent scattering , Speckle decorrelation
  • Journal title
    Medical Image Analysis
  • Serial Year
    2006
  • Journal title
    Medical Image Analysis
  • Record number