• Title of article

    Physical validation of a patient-specific contact finite element model of the ankle

  • Author/Authors

    Donald D. Anderson، نويسنده , , Jane K. Goldsworthy، نويسنده , , Wendy Li، نويسنده , , M. James Rudert، نويسنده , , Yuki Tochigi، نويسنده , , Thomas D. Brown، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    8
  • From page
    1662
  • To page
    1669
  • Abstract
    A validation study was conducted to determine the extent to which computational ankle contact finite element (FE) results agreed with experimentally measured tibio-talar contact stress. Two cadaver ankles were loaded in separate test sessions, during which ankle contact stresses were measured with a high-resolution (Tekscan) pressure sensor. Corresponding contact FE analyses were subsequently performed for comparison. The agreement was good between FE-computed and experimentally measured mean (3.2% discrepancy for one ankle, 19.3% for the other) and maximum (1.5% and 6.2%) contact stress, as well as for contact area (1.7% and 14.9%). There was also excellent agreement between histograms of fractional areas of cartilage experiencing specific ranges of contact stress. Finally, point-by-point comparisons between the computed and measured contact stress distributions over the articular surface showed substantial agreement, with correlation coefficients of 90% for one ankle and 86% for the other. In the past, general qualitative, but little direct quantitative agreement has been demonstrated with articular joint contact FE models. The methods used for this validation enable formal comparison of computational and experimental results, and open the way for objective statistical measures of regional correlation between FE-computed contact stress distributions from comparison articular joint surfaces (e.g., those
  • Keywords
    Articular joint contact , validation , ankle , Finite element
  • Journal title
    Journal of Biomechanics
  • Serial Year
    2007
  • Journal title
    Journal of Biomechanics
  • Record number

    452586