• Title of article

    False-negative frozen section of sentinel lymph node biopsy for breast cancer False-negative frozen section of sentinel lymph node biopsy for breast cancer

  • Author/Authors

    S. Holck، نويسنده , , H. Galatius، نويسنده , , U. Engel، نويسنده , , F. Wagner، نويسنده , , J. Hoffmann، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    7
  • From page
    42
  • To page
    48
  • Abstract
    A prospective study is presented of frozen section examinations (FS) performed in parallel with 265 consecutive sentinel lymph node procedures (SLNP) over a 20-month period. The final pathological study included immunohistochemistry (IHC) for keratin if the haematoxylin–eosin (HE)-stained section was tumour free. FS correctly identified node-positive or node-negative axillae in 235 cases. In 28 SLNPs the final examination gave a positive result not detected in the FS, resulting in reoperation. In 21 of these false-negative (FN) cases micrometastases (MIM) were present. There were no false-positive cases, but in two cases of lobular carcinoma the findings in the FS were equivocal, the final reports recording metastases in one but not in the other. Lobular carcinoma and other less common subtypes of carcinoma were overrepresented, ductal carcinoma not otherwise specified (NOS) being less likely to affect the FN findings.
  • Keywords
    Sentinel lymph node , breast cancer , Frozen section