• Title of article

    The calcium sensitizer levosimendan improves the function of stunned myocardium after percutaneous transluminal coronary angioplasty in acute myocardial ischemia Original Research Article

  • Author/Authors

    Steffen Sonntag، نويسنده , , Stig Sundberg، نويسنده , , Lasse Antero Lehtonen، نويسنده , , Franz Xaver Kleber، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    6
  • From page
    2177
  • To page
    2182
  • Abstract
    Objectives We assessed the effects of levosimendan on left ventricular (LV) function in patients with acute myocardial ischemia and after coronary angioplasty. Background The calcium sensitizer levosimendan improves the function of myocardium in experimental stunning. Methods Twenty-four patients with an acute coronary syndrome underwent angioplasty followed by double-blinded, randomized treatment with 24 μg/kg of levosimendan (n = 16) or placebo (n = 8). Left ventricular pressures and volumes were recorded by cineventriculography and micromanometer-tipped catheters 10 min after angioplasty before drug administration (baseline) and 20 min after drug administration. Left ventricular function was assessed by the pressure–volume loop, and regional function analysis by the Slager method. Results The number of hypokinetic segments decreased with levosimendan, from 8.9 ± 0.9 to 6.5 ± 1.1 (mean ± SEM), as compared with an increase from 7.8 ± 1.0 to 8.5 ± 1.1 with placebo (p = 0.016). A leftward and/or upward shift of the systolic part of the pressure–volume loop, indicating improved systolic function, was observed in eight of 16 of the levosimendan-treated and one of eight of the placebo patients (p = 0.178). In addition, the single-beat elastance was increased by levosimendan (p = 0.045). The pressure–volume area (p = 0.001), end-systolic pressure (p = 0.002), and volume index (p < 0.001) were decreased by levosimendan, but there was no change in the end-systolic pressure–volume ratio. End-diastolic pressure remained unchanged, whereas the end-diastolic volume index was decreased by levosimendan (p = 0.002). The time constant of isovolumic LV pressure fall decreased with levosimendan (p = 0.001). Conclusions Levosimendan improved the function of stunned myocardium without obvious impairment of diastolic function.
  • Keywords
    Acute coronary syndrome , LV , ACS , TIMI , Thrombolysis In Myocardial Infarction , left ventricle/left ventricular
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    2004
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number

    459166