• Title of article

    Functional and Morphologic Imaging of Coronary Atherosclerosis in Living Mice Using High-Resolution Color Doppler Echocardiography and Ultrasound Biomicroscopy Original Research Article

  • Author/Authors

    Johannes Wikstr?m، نويسنده , , Julia Gr?nros، نويسنده , , G?ran Bergstr?m، نويسنده , , Li-ming Gan، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    8
  • From page
    720
  • To page
    727
  • Abstract
    Objectives This study aimed to establish non-invasive methods of assessing coronary artery morphology in normal and atherosclerotic mice in vivo. Background Coronary flow velocity reserve (CFVR) has been shown to correlate with coronary minimal lumen diameter (MLD) in patients with coronary artery stenosis. In mice, there are no existing non-invasive imaging techniques allowing quantitative measurement of the coronary artery morphology and function. Methods Systemic hemodynamic effects of adenosine were studied in seven C57BL/6 mice. In 17 C57BL/6 mice, CFVR was measured in the mid left coronary artery (LCA) using either hypoxia- or adenosine-induced coronary hyperemia. Further, in another 10 atherosclerotic low-density lipoprotein receptor (LDLR)−/− mice, the hypoxia-induced CFVR was performed and proximal LCA MLD was measured using ultrasound biomicroscopy (UBM). Histologic sections of the LCA were collected. Results The adenosine dose of 160 μg/kg/min induced maximal coronary hyperemia without any systemic hemodynamic effects. Adenosine and hypoxia-induced CFVR values averaged at 2.0 ± 0.1 and 1.9 ± 0.3, respectively, in C57BL/6 mice (p = NS). In LDLR−/− mice, CFVR and MLD ranged between 1.4 to 2.9 μm and 190 to 370 μm, respectively. Histology revealed proximal lumen-narrowing plaques in the LCA. Significant correlation was found between hypoxia-induced CFVR and the MLD (p < 0.005, R2 = 0.8707). Conclusions The CDE and UBM technique can be used to measure atherosclerosis-related lumen narrowing of the LCA in living mice. These non-invasive techniques may provide us with novel tools for following up disease status in mouse coronary arteries in a quantitative manner.
  • Keywords
    BP , heart rate , blood pressure , LCA , UBM , LDLR , MLD , HR , CFR , coronary flow velocity reserve , coronary flow reserve , minimal lumen diameter , CFVR , left coronary artery , CDE , color Doppler echocardiography , low-density lipoprotein receptor , ultrasound biomicroscope
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    2005
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number

    460158