• Title of article

    Suction dressings to secure a dermal substitute

  • Author/Authors

    Winston McEwan، نويسنده , , Tim La H. Brown، نويسنده , , Stephen M. Mills، نويسنده , , Michael J. Muller، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    3
  • From page
    259
  • To page
    261
  • Abstract
    One of the problems with the dermal substitute Integra has been securing the material to the wound bed to prevent shearing and loss. Techniques to achieve stability include staples and elastic netting with an over layer of absorbent dressings that can be changed regularly. We report an effective technique using suction dressings to immobilise Integra. This technique led to firm application underlying tissue, and appeared to decrease fluid collection under the Integra. Earlier mobilisation and discharge from hospital were facilitated.
  • Keywords
    Integra , Suction dressing
  • Journal title
    Burns
  • Serial Year
    2004
  • Journal title
    Burns
  • Record number

    470654