• Title of article

    Validation of new noninvasive method (contrast-enhanced transthoracic second harmonic echo Doppler) for the evaluation of coronary flow reserve: Comparison with intracoronary Doppler flow wire

  • Author/Authors

    Carlo Caiati، نويسنده , , Cristian Montaldo، نويسنده , , Norm Zedda، نويسنده , , Robert Montisci، نويسنده , , Massimo Ruscazio، نويسنده , , Giorgio Lai، نويسنده , , Mauro Cadeddu، نويسنده , , Luigi Meloni، نويسنده , , Sabino Iliceto، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1999
  • Pages
    8
  • From page
    1193
  • To page
    1200
  • Abstract
    OBJECTIVES We tested the hypothesis that coronary flow reserve (CFR) in the left anterior descending coronary artery (LAD) as assessed by new noninvasive method (contrast-enhanced transthoracic second harmonic echo Doppler) is in agreement with CFR measurements assessed by intracoronary Doppler flow wire. BACKGROUND Contrast-enhanced transthoracic second harmonic echo Doppler is novel noninvasive method to detect blood flow velocity and reserve in the LAD. However, it has not yet been validated versus gold-standard method. METHODS Twenty-five patients undergoing CFR assessment in the LAD by Doppler flow wire were also evaluated by contrast-enhanced transthoracic Doppler to record blood flow in the distal LAD at rest and during hyperemi obtained by adenosine IV infusion. In five patients CFR was evaluated twice (before and after angioplasty). RESULTS As result of the combined use of IV contrast and second harmonic Doppler technology, feasibility in assessing coronary flow reserve equaled 100%. The agreement between the two methods was high. In fact, in all but five patients the maximum difference between the two CFR measurements was 0.38. Overall, the prediction (95%) interval of individual differences was −0.69 to +0.72. Reproducibility of CFR measurements was also high. The limits of the agreement (95%) between the two measurements were −0.32 to +0.32. CONCLUSIONS Coronary flow reserve in the LAD as assessed by contrast-enhanced transthoracic echo Doppler along with harmonic mode concurs very closely with Doppler flow wire CFR measurements. This new noninvasive method allows feasible, reliable and reproducible assessment of CFR in the LAD.
  • Keywords
    CAD , coronary artery disease , LAD , PTCA , pulsed wave , percutaneous transluminal coronary angioplasty , TEE , transesophageal echocardiography , left anterior descending coronary artery , TTE , CFR , coronary flow reserve , PW , transthoracic echocardiography , IDFW , intracoronary Doppler flow wire
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    1999
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number

    481360