• Title of article

    Optimal scan delay of arterial phase scanning of hepatic CT using a real-time image reconstruction system

  • Author/Authors

    Tadafumi Shimizu، نويسنده , , Toshimasa Misaki، نويسنده , , Kazuhiro Yamamoto، نويسنده , , Yasunori Tanaka، نويسنده , , Keita Utsunomiya، نويسنده , , Kozo Sueyoshi، نويسنده , , Isamu Narabayashi، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1999
  • Pages
    4
  • From page
    107
  • To page
    110
  • Abstract
    To optimize scan delay of arterial phase scanning of hepatic CT, 30 patients suspected of having HCC were examined using real-time image reconstruction technology (SureStart). In all cases, SureStart was successful. Despite the low dose, these images allowed adequate visualization of the abdominal aorta. The mean delay from the initiation of contrast administration to the beginning of arterial phase scanning was 29.6 ± 5.2 sec (mean ± SD; range, 22–51 sec).
  • Keywords
    Liver , CT , contrast enhancement
  • Journal title
    Clinical Imaging
  • Serial Year
    1999
  • Journal title
    Clinical Imaging
  • Record number