• Title of article

    Local staging of prostate cancer with endorectal surface coil MR imaging in a mid-field magnetic system

  • Author/Authors

    Oguz Akin، نويسنده , , Ahmet Muhtesem Agildere، نويسنده , , Hale Ersoy، نويسنده , , Haluk Ozen، نويسنده , , Ilteris Tekin، نويسنده , , Ayse Ayhan، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    5
  • From page
    47
  • To page
    51
  • Abstract
    To investigate the accuracy of endorectal surface coil magnetic resonance imaging (ecMRI) in a 1.0-T magnetic field for the local staging of prostate cancer, 25 patients were studied. In 14 Stages T1 and T2 tumors, 11 were correctly identified and 3 were overstaged. In 11 Stage T3 neoplasms, ecMRI was accurate in 7 cases, and the other 4 were understaged. The overall accuracy of ecMRI in 1.0 T was 72% and that was comparable to the reported accuracy of this technique in high-field systems.
  • Journal title
    Clinical Imaging
  • Serial Year
    2003
  • Journal title
    Clinical Imaging
  • Record number

    508566