• Title of article

    Percutaneous retrieval of 20 centrally dislodged Port-A catheter fragments

  • Author/Authors

    Juhn-Cherng Liu، نويسنده , , Hsiuo-Shan Tseng، نويسنده , , Chia-Yuen Chen، نويسنده , , Ming-Sheng Chern، نويسنده , , Cheng-Yen Chang، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    7
  • From page
    223
  • To page
    229
  • Abstract
    A total of 20 patients with centrally embolized Port-A catheter fragments underwent the percutaneous retrieval procedures at our hospital. The causes of the dislodgement of these catheters included bad connection between the port and catheter, angulation or distortion at the anastomosis site, severing the catheter during insertion and removal of the catheter, improper catheter position and fatigue of the catheter. Consequently, improper procedure handling by the inexperienced surgeons could be considered as the most frequent cause of embolization. The percutaneous retrieval procedures were successful in all centrally embolized fragments. Of 20 successful retrievals, 16 were performed will loop snare catheters and 4 with Dormia basket retrievers.
  • Keywords
    Port-A catheter , embolization , Retrieval , Loop snare , Dormia basket
  • Journal title