Title of article
CT colonography using different reconstruction modi
Author/Authors
Rainer R?ttgen، نويسنده , , Frank Fischbach، نويسنده , , Michail Plotkin، نويسنده , , Michael Lorenz، نويسنده , , Torsten Freund، نويسنده , , Ralf Jürgen Schr?der، نويسنده , , Roland R. Felix، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
5
From page
195
To page
199
Abstract
Objective
Performing computed tomography (CT) colonography, we compared different reconstruction modi for the detection of colorectal polyps.
Methods
The CT data of 48 patients using 16-slice helical CT were analysed in axial slices, virtual-endoscopy and colon-dissection modus.
Results
The sensitivity (specificity) for the detection of colonic polyps was 94% (80%) if using “colonic-dissection” tool and 89% (80%) if using “virtual-endoscopy” tool. The difference between the virtual endoscopy and colon dissection, considering polyps up to 4.9 mm, was significant.
Conclusions
Reconstruction software colon dissection improves the sensitivity of CT colonography.
Keywords
polyps , Colon dissection , 3D-reconstruction , CT colonography , computed tomography