• Title of article

    High-dose film dosimeters based on bromophenol blue or xylenol orange dyed polyvinyl alcohol

  • Author/Authors

    A. A. Abdel-Fattah، نويسنده , , S. Ebraheem، نويسنده , , M. El-Kelany، نويسنده , , F. Abdel-Rehim، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1996
  • Pages
    6
  • From page
    345
  • To page
    350
  • Abstract
    Dyed poly(vinyl alcohol) (PVA) films, prepared by a simple technique of casting acqueous solutions of PVA containing bromophenol blue (BPB) or xylenol orange (XYO) on a horizontal glass plate, are useful as routine high-dose dosimeters. These flexible plastic film dosimeters are bleached when exposed to γ-ray photons. Absorbed doses should not exceed 20 kGy for BPB/PVA film and 90 kGy for XYO/PVA film. The radiation-chemical yield (G-value) of both films was calculated and found to be 0.205 μmol/J for BPB/PVA and 0.143 μmol/J for XYO/PVA. The effects of irradiation temperature and relative humidity as well as pre- and post-irradiation storage, on the radiation responses of the films are examined. Although the response of these films depends on the irradiation temperature, these films are highly stable before and after irradiation under different storage conditions and are not affected by humidity changes in the intermediate range of relative humidity (10–60%).
  • Journal title
    Applied Radiation and Isotopes
  • Serial Year
    1996
  • Journal title
    Applied Radiation and Isotopes
  • Record number