• Title of article

    Nano-mechanics of bone and bioactive bone cement interfaces in a load-bearing model

  • Author/Authors

    G.X. Ni، نويسنده , , Y.S. Choy، نويسنده , , W.W. Lu، نويسنده , , A.H.W. Ngan، نويسنده , , Peter K.Y. Chiu، نويسنده , , Z.Y. Li، نويسنده , , B. Tang، نويسنده , , K.D.K. Luk، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    8
  • From page
    1963
  • To page
    1970
  • Abstract
    Many bioactive bone cements were developed for total hip replacement and found to bond with bone directly. However, the mechanical properties at the bone/bone cement interface under load bearing are not fully understood. In this study, a bioactive bone cement, which consists of strontium-containing hydroxyapatite (Sr-HA) powder and bisphenol-α-glycidyl dimethacrylate (Bis-GMA)-based resin, was evaluated in rabbit hip replacement for 6 months, and the mechanical properties of interfaces of cancellous bone/Sr-HA cement and cortical bone/Sr-HA cement were investigated by nanoindentation. The results showed that Youngʹs modulus (17.6±4.2 GPa) and hardness (987.6±329.2 MPa) at interface between cancellous bone and Sr-HA cement were significantly higher than those at the cancellous bone (12.7±1.7 GPa; 632.7±108.4 MPa)and Sr-HA cement (5.2±0.5 GPa; 265.5±39.2 MPa); whereas Youngʹs modulus (6.3±2.8 GPa) and hardness (417.4±164.5 MPa) at interface between cortical bone and Sr-HA cement were significantly lower than those at cortical bone(12.9±2.2 GPa; 887.9±162.0 MPa), but significantly higher than Sr-HA cement(3.6±0.3 GPa; 239.1±30.4 MPa). The results of the mechanical properties of the interfaces were supported by the histological observation and chemical composition. Osseointegration of Sr-HA cement with cancellous bone was observed. An apatite layer with high content of calcium and phosphorus was found between cancellous bone and Sr-HA cement. However, no such apatite layer was observed at the interface between cortical bone and Sr-HA cement. And the contents of calcium and phosphorus of the interface were lower than those of cortical bone. The mechanical properties indicated that these two interfaces were diffused interfaces, and cancellous bone or cortical bone was grown into Sr-HA cement 6 months after the implantation.
  • Keywords
    Bioactive bone cement , Nanoindentation , Mechanical property , Interface , Total hip arthroplasty
  • Journal title
    Biomaterials
  • Serial Year
    2006
  • Journal title
    Biomaterials
  • Record number

    546839