• Title of article

    Three-dimensional nonfluoroscopic mapping and ablation of inappropriate sinus tachycardia: Procedural strategies and long-term outcome

  • Author/Authors

    Nassir F. Marrouche، نويسنده , , Salwa Beheiry، نويسنده , , Gery Tomassoni، نويسنده , , Christopher Cole، نويسنده , , Dianna Bash، نويسنده , , Thomas Dresing، نويسنده , , Walid Saliba، نويسنده , , Ahmad Abdul-Karim، نويسنده , , Patrick Tchou، نويسنده , , Robert Schweikert، نويسنده , , Fabio Leonelli، نويسنده , , Andrea Natale، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2002
  • Pages
    9
  • From page
    1046
  • To page
    1054
  • Abstract
    Objectives We conducted this study to assess long-term results of three-dimensional (3-D) mapping-guided radiofrequency ablation (RFA) of inappropriate sinus tachycardia (IST). Change in activation after the administration of esmolol was also assessed and compared to the shift documented with successful sinus node (SN) modification. Background The long-term results after RFA of IST have been reported to vary between 27% and 66%. Methods Thirty-nine patients (35 women, mean age 31 ± 9 years) with debilitating IST were included in the study. The area around the earliest site of activation recorded using the 3-D mapping system was targeted for ablation. The shift in the earliest activation site after administration of esmolol was compared with the shift after RFA. Results The heart rate at rest and in drug-free state ranged between 95 and 125 beats/min (mean 99 ± 14 beats/min). Sinus node was successfully modified in all patients. Following ablation, the mean heart rate dropped to 72 ± 8 beats/min, p < 0.01. The extent of the 3-D shift in caudal activation along the crista terminalis was more pronounced after RFA than during esmolol administration (23 ± 11 mm vs. 7 ± 5 mm, respectively, p < 0.05). No patient required pacemaker implantation after a mean follow-up time of 32 ± 9 months; 21% of patients experienced recurrence of IST and were successfully re-ablated. Conclusions Three-dimensional electroanatomical mapping seems to facilitate and improve the ablation results of IST. The difference in caudal shift seen after esmolol administration and following SN modification suggests that adrenergic hypersensitivity is not the only mechanism responsible for the inappropriate behavior of the SN.
  • Keywords
    IST , RFA , inappropriate sinus tachycardia , radiofrequency ablation , 3-D , Sinus node , RFA , three-dimensional , CT , crista terminalis , ECG , SN , electrocardiogram/electrocardiographic , electrophysiologic study , ice , intracardiac echocardiography , EPS
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    2002
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number

    597187