• Title of article

    Electrocardiogram-gated single-photonemission computed tomography versus cardiacmagnetic resonance imaging for the assessmentof left ventricular volumes and ejection fraction: A meta-analysis

  • Author/Authors

    John P.A. Ioannidis، نويسنده , , Thomas A. Trikalinos، نويسنده , , Peter G Danias، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2002
  • Pages
    10
  • From page
    2059
  • To page
    2068
  • Abstract
    Objectives The purpose of this study was to evaluate the accuracy of electrocardiogram (ECG)-gated single-photon emission computed tomography (SPECT) for assessment of left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) compared with the gold standard of cardiac magnetic resonance imaging (MRI). Background Several comparisons of ECG-gated SPECT with cardiac MRI have been performed for evaluation of LV volumes and EF, but each has considered few subjects, thus leaving uncertainty about the frequency of discrepancies between the two methods. Methods We performed a meta-analysis of data on 164 subjects from nine studies comparing ECG-gated SPECT versus cardiac MRI. Data were pooled in correlation and regression analyses relating ECG-gated SPECT and cardiac MRI measurements. The frequency of discrepancies of at least 30 ml in EDV, 20 ml in ESV and 5% or 10% in EF and concordance for EF ≤40% versus >40% were determined. Results There was an overall excellent correlation between ECG-gated SPECT and cardiac MRI for EDV (r = 0.89), ESV (r = 0.92) and EF (r = 0.87). However, rates of discrepancies for individual subjects were considerable (37% [95% confidence interval {CI}, 26% to 50%] for at least 30 ml in EDV; 35% [95% CI, 23% to 49%] for at least 20 ml in ESV; 52% [95% CI, 37% to 63%] for at least 5% in EF; and 23% [95% CI, 11% to 42%] for at least 10% in EF). The misclassification rate for the 40% EF cutoff was 11%. Conclusions Electrocardiogram-gated SPECT measurements of EDV, ESV and EF show high correlation with cardiac MRI measurements, but substantial errors may occur in individual patients. Electrocardiogram-gated SPECT offers useful functional information, but cardiac MRI should be used when accurate measurement is required.
  • Keywords
    end-diastolic volume , EF , ejection fraction , ESV , end-systolic volume , LV , MRI , left ventricle/ventricular , magnetic resonance imaging , CAD , SEE , coronary artery disease , Standard error of estimate , CI , SPECT , ECG , Electrocardiogram , EDV , Confidence interval , Single-photon emission computed tomography
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    2002
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number

    597354