• Title of article

    Aortic wall alterations after use of gelatin-resorcinol-formalin glue

  • Author/Authors

    Matthias Kirsch، نويسنده , , Maryvonne Ginat، نويسنده , , Laure Lecerf، نويسنده , , Rémi Houel، نويسنده , , Daniel Loisance، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2002
  • Pages
    3
  • From page
    642
  • To page
    644
  • Abstract
    We report the case of a patient who underwent reoperation 8 years after aortic valve replacement because of aneurysmal dilatation of the aortic root. During the initial intervention, gelatin-resorcinol-formalin glue had been applied on the outside of the aortic root. Perioperative examination revealed a necrotic appearance of the right coronary sinus, with contained ruptures at two different sites. Histologic analysis showed major destruction of the aortic root media, leading to vascular wall thinning and rupture. The use of gelatin-resorcinol-formalin glue may expose patients to major alterations of the aortic wall.
  • Journal title
    The Annals of Thoracic Surgery
  • Serial Year
    2002
  • Journal title
    The Annals of Thoracic Surgery
  • Record number

    605386