• Title of article

    Successful stent-grafting for perforation of the thoracic aorta by an intraaortic balloon pump

  • Author/Authors

    Victor Bautista-Hernandez، نويسنده , , Javier Moya، نويسنده , , Jorge Martinell، نويسنده , , Maria Luz Polo، نويسنده , , Juli?n Fraile، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2002
  • Pages
    3
  • From page
    956
  • To page
    958
  • Abstract
    Vascular complications associated with intraaortic balloon pump placement are quite common and predominantly related to femoral or iliac damage. Iatrogenic injury of the thoracic aorta is less usual and often fatal. Surgery for the lesions of the descending thoracic aorta still has a relatively high morbidity and mortality. Endovascular covered stent-graft prostheses have become a less invasive therapeutic approach to lesions of the thoracic aorta, especially in patients with high surgical risk. We describe a case of perforation of the thoracic aorta caused by an intraaortic balloon pump. The injury was confirmed by aortography and successfully repaired by implantation of an endovascular stent-graft via the left common iliac artery.
  • Journal title
    The Annals of Thoracic Surgery
  • Serial Year
    2002
  • Journal title
    The Annals of Thoracic Surgery
  • Record number

    605467