• Title of article

    Mass regression in aortic stenosis after valve replacement with small size pericardial bioprosthesis

  • Author/Authors

    Giordano Tasca، نويسنده , , Federico Brunelli، نويسنده , , Marco Cirillo، نويسنده , , Andrea Amaducci، نويسنده , , Zen Mhagna، نويسنده , , Giovanni Troise، نويسنده , , Eugenio Quaini، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    7
  • From page
    1107
  • To page
    1113
  • Abstract
    Background The aim of the study was to determine whether left ventricular mass regression is influenced by valve size after the implantation of a Carpentier-Edwards Perimount (CEP) pericardial bioprosthesis for pure aortic stenosis. Methods Patients receiving 19-mm, 21-mm, and 23-mm CEP aortic valves underwent echocardiography preoperatively and at least 1 year after surgery (mean, 2.3 ± 1 years) and the echocardiograms were compared within and between groups. Results The study involved a total of 88 patients: 34 receiving 19-mm CEPs, 29 receiving 21-mm CEPs, and 25 receiving 23-mm CEPs. The mean postoperative prosthetic gradients were respectively 20.6 ± 6.6 mm Hg, 17.9 ± 5.8 mm Hg, and 13.2 ± 4.1 mm Hg (p = 0.0001); the mean postoperative valve areas were respectively 1.24 ± 0.16 cm2, 1.45 ± 0.2 cm2, and 1.63 ± 0.21 cm2 (p = 0.0001). In comparison with the preoperative echocardiographic measurements absolute left ventricular mass significantly decreased by −54.1 ± 48.8 g, −54.1 ± 55.1 g, and −74.4 ± 57.4 g respectively with no statistically significant between-group difference (analysis of variance) but ventricular septum and posterior wall thickness significantly decreased in each group (p< 0.05). Conclusions The implantation of 19-mm, 21-mm, and 23-mm CEP aortic prostheses significantly reduces left ventricular mass without any size-related differences.
  • Journal title
    The Annals of Thoracic Surgery
  • Serial Year
    2003
  • Journal title
    The Annals of Thoracic Surgery
  • Record number

    606945