• Title of article

    Noninvasive evaluation of arterial grafts with newly released multidetector computed tomography

  • Author/Authors

    Jacob Gurevitch، نويسنده , , Tamar Gaspar، نويسنده , , Boris Orlov، نويسنده , , Ron Amar، نويسنده , , Dan Dvir، نويسنده , , Nathan Peled، نويسنده , , Dan J Aravot، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    5
  • From page
    1523
  • To page
    1527
  • Abstract
    Background High-quality postoperative imaging of bypass conduits is essential when evaluating different types of conduits, anastomoses, and surgical techniques. We investigated the potential value of the newest generation of multidetector-row computer tomographic scanners in assessing bypass grafts. Methods From June to September 2002, 14 patients underwent scanning with a newly released 16-slice computed tomographic scanner (Mx8000 IDT; Philips Medical Systems) after coronary artery bypass grafting. Four patients had had minimally invasive direct coronary artery bypass grafting and 3, redo coronary artery revascularization. Contrast-enhanced computed tomographic angiography was performed using retrospective electrocardiographic gating. Scan length was 22 to 30 cm, and total scan time was 27 to 37 seconds. Results Of the 14 patients, 8 were scanned within 1 week after operation and 6, 1 month to 12 months postoperatively. Average heart rate during the scan was 82 beats per minute (range, 60 to 97 beats per minute), and all patients were able to hold their breath for the required time. Thirty conduits were studied: 26 arterial (18 in situ left and right internal mammary artery grafts, five free right internal mammary and radial artery grafts, and three in situ right gastroepiploic artery grafts) and four vein grafts. Excellent visualization of all 30 grafts was achieved. Thirty-four of the 35 distal anastomoses were patent; one vein graft was occluded. Conclusions This new technology is a promising noninvasive measure to evaluate patency of bypass conduits, including the gastroepiploic artery where catheterization is usually difficult. The ability to display the vessel wall as well as its lumen might distinguish radial artery spasm from intimal hyperplasia. The superb resolution and increased scan length required to cover the entire internal mammary artery grafts—from origin to distal anastomoses—can be achieved easily in a single breath-holding owing to the increased number of slices per rotation and shortening of the gantry rotation time.
  • Journal title
    The Annals of Thoracic Surgery
  • Serial Year
    2003
  • Journal title
    The Annals of Thoracic Surgery
  • Record number

    607034