• Title of article

    Tube-Graft Inversion for the Construction of an “Open” Distal Anastomosis During Ascending Aortic Replacement: A New Technique

  • Author/Authors

    Christos Alexiou، نويسنده , , Andrzej W. Sosnowski، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    3
  • From page
    326
  • To page
    328
  • Abstract
    For the construction of a distal “open” anastomosis during ascending aortic replacement, a tube-graft is placed opposite to the transected aorta. We describe an alternative technique. The tube-graft is inverted and positioned within the aortic arch in a way that brings the entire circumference of the distal end of the tube-graft next to the circumference of the transected aorta. An end-to-end anastomosis is then fashioned with a running suture, the needle of which goes through the aorta and the tube-graft in a single pass. This technique permits easy, accurate, and fast suture placement, producing a hemostatic distal anastomosis within a short circulatory arrest time.
  • Journal title
    The Annals of Thoracic Surgery
  • Serial Year
    2007
  • Journal title
    The Annals of Thoracic Surgery
  • Record number

    610352