Title of article
Anastomosis to the wrong vessel during off-pump bypass surgery via mini-thoracotomy
Author/Authors
Christof Schmid، نويسنده , , Tonny D. T. Tjan، نويسنده , , Karl J. Henrichs، نويسنده , , Dietrich Boppert، نويسنده , , Hans H. Scheld، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1999
Pages
2
From page
831
To page
832
Abstract
Recently, minimally invasive coronary artery bypass graft operation has been established as a new treatment strategy for cardiac surgeons. We report on a patient who underwent off-pump coronary artery bypass graft operation through a mini-thoracotomy to the wrong coronary artery (first diagonal) with consecutive successful percutaneous transluminal coronary angioplasty of the vessel involved (left anterior descending coronary artery) to demonstrate a special risk that is associated with this kind of operation.
Journal title
The Annals of Thoracic Surgery
Serial Year
1999
Journal title
The Annals of Thoracic Surgery
Record number
615783