Title of article
Impaired distensibility of neoaorta after arterial switch procedure
Author/Authors
Tomoaki Murakami، نويسنده , , Makoto Nakazawa، نويسنده , , Kazuo Momma، نويسنده , , Yasuharu Imai، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2000
Pages
4
From page
1907
To page
1910
Abstract
Background. Although the arterial switch operation has become the standard surgical procedure for treatment of complete transposition, postoperative problems have not been fully appreciated. One such problem may be the postoperative function of great arteries that are manipulated radically.
Methods. The diameters at four levels of the aorta were measured in 36 patients who had undergone arterial switch operation and the distensibilities were calculated. The data were compared with that of age-matched controls.
Results. At the level of the Valsalva sinus, aortic diameters after one-staged and two-staged operations were 137.0% ± 21.3%N and 152.4% ± 17.7%N of the normal aorta, respectively. The distensibilities at the Valsalva sinus in patients after one-staged and two-staged operations were 1.2 ± 0.7 and 1.5 ± 0.8 cm2 • dyn−1 • 10−6, and at the supraaortic ridge were 2.5 ± 1.5 and 1.9 ± 1.5 cm2 • dyn−1 • 10−6, respectively.
Conclusions. In patients after arterial switch procedure, the distensibility of the base of aorta is decreased. Long-term follow-up is necessary to clarify the influence of the “stiffness” of the base of aorta.
Journal title
The Annals of Thoracic Surgery
Serial Year
2000
Journal title
The Annals of Thoracic Surgery
Record number