Title of article
Hemodynamic parameters of failing infrainguinal bypass grafts,
Author/Authors
George Papanicolaou and Leonid Ryzhik، نويسنده , , R. Eugene Zierler، نويسنده , , Kirk W. Beach، نويسنده , , Janette A. Isaacson، نويسنده , , D.Eugene Strandness Jr، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1995
Pages
7
From page
238
To page
244
Abstract
Purpose
To assess the relationship of duplex ultrasound hemodynamic parameters in stenotic vein grafts with events such as graft thrombosis or surgical revisions.
Patients and methods
We studied 35 patent infrainguinal bypass grafts that were observed by means of color duplex graft mapping using a surveillance protocol.
Conclusion
We conclude that stenotic vein grafts with a focal peak systolic velocity of at least 250 cm/s or a velocity ratio of at least 3.4 are at increased risk for thrombosis or need for revision. Asymptomatic stenotic vein grafts with focal peak systolic velocities and ratios less than the above values may be safely observed without immediate risk for thrombosis