• Title of article

    Use of Steady-State Pump Head-Discharge Curve for Unsteady Pipe Flow Applications

  • Author/Authors

    Al-Khomairi، A. M. نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    -1000
  • From page
    1001
  • To page
    0
  • Abstract
    An experimental pipeline system with a multistage centrifugal pump was used to study the effect of transient operations on the hydrodynamic performance of a centrifugal pump. Several transient flow operations were considered, ranging from very mild to severe transients. The dynamic relationship of total pressure rise across the pump to the flow rate was compared with that of the steady state. Deviation between the dynamic pump head and the value given by the steady-state curve at the same instantaneous discharge was established and found to be a function of the severity of the transient. It was found that severe flow conditions could cause this deviation to exceed 30% of the steady-state value. The use of the steady-state pump headdischarge relationship in the solution of transient pipe flow by the method of characteristics (MOC) is discussed. It was found that the steady-state pump head-discharge curve was not accurate enough to support the solution of unsteady pipe flow application by the MOC.
  • Keywords
    Hydrograph
  • Journal title
    JOURNAL OF HYDROULIC ENGINEERING
  • Serial Year
    2003
  • Journal title
    JOURNAL OF HYDROULIC ENGINEERING
  • Record number

    63422