Title of article
Validation of a multicenter computer-based surveillance system for hospital-acquired bloodstream infections in neonatal intensive care departments
Author/Authors
Philip L. Graham III، نويسنده , , Pablo San Gabriel، نويسنده , , Suzanne Lutwick، نويسنده , , Janet Haas، نويسنده , , Lisa Saiman، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
3
From page
232
To page
234
Abstract
Automated systems can facilitate surveillance for health care–associated infections. The New York Antimicrobial Resistance Project (NYARP) electronically monitors trends in bloodstream infections from 6 medical centers in New York, NY. To validate NYARPʹs data, episodes of health care–associated bloodstream infections detected by this system were compared with those obtained by an infection control practitioner performing an unrelated study in 2 participating neonatal intensive care departments. The sensitivity (84%), specificity (99%), and positive (84%) and negative (99%) predictive values of NYARP were excellent when coagulase-negative staphylococcal bloodstream infections were removed.