  • Abstract
    OBJECTIVE: Pulmonary hypoplasia is common in compromised pregnancies. However, prenatal diagnosis by volume measurement has not become routine until now. The performance of three-dimensional ultrasonography in fetal lung volume determination was evaluated in this study. STUDY DESIGN: In a total of 78 singleton pregnancies 108 measurements were performed. Lung volume was calculated by subtraction of the fetal heart volume from the volume of the fetal thorax. RESULTS: Linear regression of transformed fetal lung volume growth gave best results (R2 = 0.77, p < 0.001), ranging from 2.8 ml at 14 weeksʹ gestation to 148 ml at term. CONCLUSION: Three-dimensional ultrasonography provides not only access to surface rendered images but it also enables more sophisticated volume measurements. In this study three-dimensional ultrasonography provided fast, easy access for volume estimation of the fetal lung. This technique can be used to reasonably predict fetal lung volume. (Am J Obstet Gynecol 1996;175:588-92.)