Title of article
A Study on Local Static Hold-up in a Rotary Disc Contactor Liquid-liquid Extraction Column; Part I: Single Drop Experiments
Author/Authors
Hoda Molavi، نويسنده , , Marzieh Amanabadi، نويسنده , , Sima Hosseinpoor، نويسنده , , Hossein Bahmanyar، نويسنده , , Mojtaba Shariaty-Niasar، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2010
Pages
8
From page
5191
To page
5198
Abstract
A 28 compartment liquid-liquid extraction Rotary Disc Contactor (RDC) with 9.1cm inner diameter was used in the experiments. The amount of static hold-up in five specific locations, for six specific speeds and three different sizes of droplets by using Water-Toluene chemical system based on single-droplet experiments was measured. Five correlations between the amount of local static holdup, drop diameter and rotor speed were proposed to estimate the amount of static hold-up in different locations of the column
Keywords
Single drops experiment , Rotary disc contactor , Local static hold up