Title of article
Emissions from simulated deep-seated fires in domestic waste Original Research Article
Author/Authors
Anders L?nnermark، نويسنده , , Per Blomqvist، نويسنده , , Stellan Marklund، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
14
From page
626
To page
639
Abstract
The emissions from deep-seated fires in domestic waste have been investigated. The gas phase yields of PAH, PCDD/F, PCB, HCB, particles, and metals associated to the particulate matter were analysed during a series of simulated deep-seated fires. The method of extinguishment was varied and in cases where water was used for extinguishment, the runoff water was analysed for PAH, PCDD/F, PCB, hexachlorobenzene, and metals. In total six tests were performed. In four of the tests, samples of the fire residue were analysed for PCDD/F, PCBs, and chlorobenzenes.
Keywords
Fire , Waste , PCDD/F , PCB , Extinguishing water , PAH
Journal title
Chemosphere
Serial Year
2008
Journal title
Chemosphere
Record number
725676
Link To Document