• Title of article

    Comparison of models for describing measured VOC emissions from wood-based panels under dynamic chamber test condition

  • Author/Authors

    J. P. Zhu، نويسنده , , J. S. Zhang، نويسنده , , C. Y. Shaw، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2001
  • Pages
    5
  • From page
    1253
  • To page
    1257
  • Abstract
    Measured emission factors are the experimental data used to represent emission characteristics of volatile organic compounds (VOCs) from testing materials under dynamic chamber test conditions. A simple empirical model that describes the measured emission factors will be very useful for practical purposes. In this study, a power law model was compared with a widely used first-order exponential decay model in their ability to describe measured emission factors of wood-based panel materials. It was demonstrated that the power law model is a better choice than the first-order model for describing emission characteristics for short-term (less than 100 h) experimental data. The power law model was also more superior in predicting long-term (up to 900 h) emission factors.
  • Keywords
    First order , emission factor , Power law , VOC , Decay constant , Indoor material
  • Journal title
    Chemosphere
  • Serial Year
    2001
  • Journal title
    Chemosphere
  • Record number