Title of article
New type of impactor with a cooled impaction plate for capturing PM2.5 and other aerosols
Author/Authors
Byung-Uk Lee، نويسنده , , Sang Soo Kim، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2003
Pages
6
From page
957
To page
962
Abstract
A new type of impactor with a cooled impaction plate was suggested by Lee and Kim (J. Aerosol Sci. 32 (2001) 107). The impactor performed well without coating material by using just the cooling impaction plate. However, the mechanism in the impactor was not elucidated by the experimental method. In this study, this kind of impactor specifically designed for capturing PM2.5 is presented. To understand the mechanism, two kinds of experiments were conducted. The experimental results show the condensation effect to be more effective than the thermophoresis effect in reducing the rebounce in the cooled plate impactor. Furthermore, this kind of impactor could be applied to PM2.5 classification.
Keywords
impactor , Cooled impaction plate , Thermoelectric module , condensation , PM2.5 , Thermophoresis