Title of article
Time course shift in particle penetration characteristics through capillary pore membrane filters
Author/Authors
Naomichi Yamamoto، نويسنده , , Minoru Fujii، نويسنده , , Kazukiyo Kumagai، نويسنده , , Yukio Yanagisawa، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2004
Pages
11
From page
731
To page
741
Abstract
The time course change in particle penetration through capillary pore membrane filters was investigated for relatively short filtration periods. In the laboratory experiments, penetration efficiencies of the 0.3 and 1.0 μm standard particles through the 2.0 μm capillary filter were continuously monitored. While penetration efficiencies of both 0.3 and 1.0 μm particles decreased, 1.0 μm particles became selectively captured by the filter. Furthermore, even small amount of collected particles (coverage fractions less than 1% of the filter surface) was found to alter particle penetration characteristics possibly because of the intense accumulations around the rims of capillary pores due to significance of particle interception. No distinct effect by addition of clogging particles of 2.0 μm diameter was observed, indicating the change in particle penetration characteristics was initiated even when particle clogs became important. The present study showed the size distribution of collected particles by capillary pore membrane filters could be biased with time even for short sampling duration.
Keywords
Standard particle , size distribution , Penetration efficiency , Interception , Time course shift