Title of article
Generation of C60 nanoparticle aerosol in high mass concentrations
Author/Authors
Amit Gupta، نويسنده , , William C. Forsythe، نويسنده , , Mark L. Clark، نويسنده , , Jeffrey A. Dill، نويسنده , , Gregory L. Baker، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2007
Pages
12
From page
592
To page
603
Abstract
The generation of nanoparticles at concentrations sufficient to perform toxicology studies is highly challenging. The vaporization/condensation technique has successfully been used previously to generate nanoparticle aerosol. However, the maximum mass concentrations generated were low , and the generation method produced aerosol having a mixed chemical composition. In this study, a new, dynamically operated, nanoparticle generation system has been developed that generates nanoparticles having a count median diameter of 40–60 nm and continuously delivers a mass concentration as high as at the nose exposure port of a nose only exposure system. This system generated nanoparticles by using an inline tube furnace for flash vaporizing micron-sized particles fed continuously from an aerosol generator. This paper describes both the experiments and the operating conditions used for generating nanoparticles to demonstrate the systemʹs capability and the methods used for physicochemical characterization of the resulting nanoparticles.
Keywords
Buckminsterfullerenes , Nanoparticles , C60 , High concentration , Inhalation Toxicology
Journal title
Journal of Aerosol Science
Serial Year
2007
Journal title
Journal of Aerosol Science
Record number
743229
Link To Document