• Title of article

    Passive measurement of coarse particulate matter, PM10–2.5

  • Author/Authors

    Darrin K. Ott، نويسنده , , William Cyrs، نويسنده , , Thomas M. Peters، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2008
  • Pages
    12
  • From page
    156
  • To page
    167
  • Abstract
    This work developed a passive sampling method to measure ambient PM10–2.5. The coefficient of variation (CV) of PM10–2.5 measured with collocated passive samplers was 20.1% in laboratory tests and 11.6% in field tests. PM10–2.5 measured passively deviated from that measured with a filter-based dichotomous sampler by 29% in field tests. The strong correlation between PM10–2.5 derived passively with the dichotomous sampler (r=0.97) suggests that the bias observed in field tests was systematic and may be empirically corrected. The limit of detection of the method was determined to be for a 5-day sample. A bootstrap analysis suggests that at least 300 particles should be imaged to stabilize the analytical variability of the method. Repeated analysis suggests that the CV for the analytical method is 5%. This method offers an inexpensive means to assess PM10–2.5 that may be incorporated into compliance networks or epidemiological studies.
  • Keywords
    Coarse particulate matter , AEROSOL , PM10.2.5 , passive sampling
  • Journal title
    Journal of Aerosol Science
  • Serial Year
    2008
  • Journal title
    Journal of Aerosol Science
  • Record number