• Title of article

    Sources of sampling error for field measurement of nitric acid gas by a denuder system

  • Author/Authors

    Hsunling Bai، نويسنده , , Chungsying Lu، نويسنده , , Kuan-Foo Chang، نويسنده , , Guor-Cheng Fang، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    7
  • From page
    941
  • To page
    947
  • Abstract
    Field measurements of atmospheric HNO3 gas by a denuder system equipped with four annular denuders were conducted in Taiwan. The positive errors from interfering N-compounds as well as the negative errors from incompleteness of the apparent absorption of the HNO3 gas, as sampled by one NaCl-denuder, were quantitatively determined and the error sources were identified.It is found that the concentrations of positive error and negative error might cancel each other resulting in less difference between the measured and the true HNO3 concentrations. The atmospheric HNO3 concentration and the ambient temperature were the major factors that influence the degree of negative errors. The apparent absorption efficiency might decrease to less than 80% if the HNO3 gas concentration were lower than 0.3 μg m−3 or the ambient temperature were over 28°C. There are also evidences showed that the positive errors were from both interfering N-containing gases and nitrate-containing particles.
  • Keywords
    Sampling Error , Absorption efficiency , Diffusion denuder , nitrous acid , Ammonium nitrate
  • Journal title
    Atmospheric Environment
  • Serial Year
    2003
  • Journal title
    Atmospheric Environment
  • Record number

    757493