Title of article
Determination of total chromium in environmental water samples
Author/Authors
Jeffrey L. Parks، نويسنده , , Laurie McNeill، نويسنده , , Michelle Frey، نويسنده , , Andrew D. Eaton، نويسنده , , Ali Haghani، نويسنده , , Lisa Ramirez، نويسنده , , Marc Edwards، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
12
From page
2827
To page
2838
Abstract
It is often desirable to quantify both dissolved Cr(VI) and total Cr in samples accurately. Various protocols are now being utilized to quantify the amount of total chromium in natural waters and each of these has possible interferences. This study describes the shortcomings of each method when particulate iron is present in a water sample, and a more rigorous digestion protocol is tested. Data from bench studies as well as a field survey of 21 water utilities are presented. Additionally, field data from several hundred water utility samples are presented to illustrate the potential for incomplete recovery of total chromium using accepted protocols.
Keywords
Sampling protocol , Hexavalent chromium , Total chromium
Journal title
Water Research
Serial Year
2004
Journal title
Water Research
Record number
769083
Link To Document